Megger TTR310 Three-Phase Transformer Turns Ratio Test Set

MEGGER TTR310 Three-Phase Transformer Turns Ratio Test Set 
  • Stand-alone or remote-control operation
  • Accurately measures ratio, phase deviation and excitation current
  • Works in the presence of high interference/high voltage

Product Details

MEGGER TTR310 Three-Phase Transformer Turns Ratio Test Set

Stand-alone or remote-control operation, Accurately measures ratio, phase deviation and excitation current, Field upgradeable without compromise to calibration, Built-in capability for storing and downloading test results in an XML format, via RS-232, Ethernet or USB ports (depending on model), Works in the presence of high interference/high voltage, Highest ratio measurement (45,000:1); highest accuracy (0.1%), Displays % error vs. name plate with pass/fail limits

The TTR310 of three-phase transformer turns ratio test sets are designed to measure the turns ratio of power, instrument, and distribution transformers in a substation or manufacturing environment. A rugged and robust design makes these instruments well suited for use in a variety of harsh environments. Our leads are specially designed to provide the necessary flexibility needed in cold weather.

The TTR310 are ideal for use by power transformer manufacturers. Their unique testing procedures and storage capability allows an operator to set up and test difficult three-phase transformers (with multiple tap changers and bushing CTs) in a fraction of the time than it used to take with other TTRs. This test also includes a pass/fail limit of individual ratios.

MIRUS Harmony-1E Isolation Transformers and Auto Transformers HARMONYâ„¢ SERIES isolation transformers and autotransformers combine very low zero sequence impedance outputs with phase shift...
MIRUS Drive 18 Transformers Multiple output auto or isolation transformers ideally suited for reduction of harmonics generated by VFDs or other 3-phase rectifier loads. Drive 12/24â„¢ pr...
MIRUS Neutral Current Eliminator (NCE) A 3-phase, low zero sequence impedance autotransformer, which when connected near to and in parallel with the harmonic generating non-linear loads (...
MIRUS Lineator 1Q3 1-Phase to Quasi 3-Phase Harmonic Filter The only passive harmonic filter designed for 3-phase VFD's operating on a 1-phase supply. In remote locations such as farms...
MIRUS Drive 24 Transformers Multiple output auto or isolation transformers ideally suited for reduction of harmonics generated by VFDs or other 3-phase rectifier loads. Drive 12/24â„¢ pr...