Free Call Australia : 1 800 834 991

Related Products

FLIR i50 Thermal Imaging Infrared Camera

HIGH VOLTAGE VLF-200CMF Very Low Frequency AC Hipot 
  • It can also be used as the voltage source for diagnostic cable testing
  • It offers the most portable, affordable, and easiest to use VLF hipots available
  • A VLF hipot is just an AC output tester but with an output frequency of 0.1 Hz

Product Details

HIGH VOLTAGE VLF-200CMF Very Low Frequency AC Hipot

VLF Test Sets from 28kV – 200kV with Sine Wave Output HVI offers the most portable, affordable, and easiest to use VLF hipots available. HVI offers the largest selection of models in the world, with ratings from 28kV – 200kV with load ratings from 0.4mF – 50mF. Since 1998, HVI has been the world's leading source for VLF test equipment. HVI is the VLF company, with nearly 1000 units shipped to over 60 countries.Patent protected under United States Patent No. 6169406.A VLF hipot is just an AC output tester but with an output frequency of 0.1 Hz or lower rather than 50/60Hz. Although the frequency is very low, it is still an alternating current with polarity reversals every half cycle. At 0.1 Hz output, rather than 60Hz, it takes 600 times less current and power to apply an AC voltage to a capacitive load, like a long cable. There is no better way to verify the AC integrity of a cable than to hipot it with AC voltage. VLF hipots are used to provide a go/no-go, or pass/fail, voltage withstand test. It can also be used as the voltage source for diagnostic cable testing. Contact HVI for more on Tan Delta and Partial Discharge measurement accessories. HVI provides the best methods of cable testing.

MEGGER Resonating Inductor Expands the range of Capacitance and Dissipation Factor (Power Factor) Test Sets. Capable of tuning capacitances up to 1µF at 10 kV. Hand-crank tuning wheel. Co...
MEGGER CB-100 Low Voltage Capacitance Lightweight and portable, 100-Hz test frequency & 30-V output voltage . Designed for testing in the laboratory, shop or substation, Model CB-100 i...
OMICRON CP TD1 Capacitance/Dissipation Factor Testing Device (Tan Delta) Combined with the CPC 100, the CP TD1 measures the capacitance and dissipation factor (power factor) with laborato...
MEGGER DELTA 2000 10-kV Automated Insulation Power Factor Test Set Extremely easy-to-use with no extensive hardware or software setup. Designed to work in high interference switchyards of...
MEGGER DELTA4110 Series 12 kV Insulation Diagnostic System Automatic and manual operation. Accurate and repeatable measurement results with high noise suppression. Lightweight, rugged two...