MIRUS GENLINK Dissimilar Pitch Neutral Limiter

GENLINK DPNL is a multiple winding reactor and when installed in the common neutral of paralleled sources either between the dissimilar generators or the generator and the Utility supply it can greatly reduce the neutral circulating currents that result from the instantaneous voltage differences. These neutral circulating currents, which are predominantly triple frequency, have the potential to cause a considerable amount of damage with respect to overheating generators and causing false-protection trips.

Voltage differences in paralleled generators made by different manufacturers or differences in standard pitch design configurations in generators made by the same manufacturer can result in heavy neutral circulating currents. Additionally, alternative energy sources such as solar and wind power that generates AC power can introduce heavy circulating currents in 4-wire parallel applications. GENLINK when applied, will impede the flow of circulating currents while adding only minimal impedance to the fault current path.

GENLINK DPNL can be used in both 3-wire and 4-wire systems. For 4-wire applications where there is return neutral current from 1-Ph loads, the DPNL must be sized for this current as well as the circulating current. For 3-wire applications where there is no return neutral current from 1-Ph loads, a smaller size DPNL can be used. Grounding of the neutral must be done at only one location which is recommended to be the distribution switchboard.

Features

• Inserts >40% impedance in neutral current circulating path
• Reduces neutral circulating current by >75%
• Adds <1% saturated impedance to 1-Ph fault path
• No impedance to 3-Ph fault path
• Use in 3-wire or 4-wire applications or any parallel source application with a common neutral and dissimilar voltage waveforms
• Eliminates generator overheating and false protection trips caused by triple frequency circulating currents
• Easy to install
• Reliable and proven performance

PONOVO T200A Single Phase Relay Tester T200A is a relay test kit based on PWM technology. The single phase relay tester has numerous powerful features. Features • High power current sou...
MEGGER Programma SVERKER760 Relay Test Set High current/high power output, Freeze and hold readings, Interconnect up to three test sets for three phase relays, Read external volts and cur...
MEGGER AVTS 4.0 Advanced Visual Test Software Powerful, easy-to-use Microsoft Windows 2000/XP/VistaTM/7 compatible. Designed to manage all aspects of protective relay testing using the MP...
MEGGER GOOSER IEC 61850 Test System Reliable testing of IEC61850 relays using a conventional relay test set. Separate Ethernet ports for the substation LAN and the controlling PC forming ...
EuroSMC PTE FCL / PTE-FCN Variable Voltage, Frequency and Phase Angle sources The PTE-FCL is an independent adjustable voltage source that can be installed inside the PTE-100-C's lid in a...