WUHAN HUAYING VLF 50KV Very Low Frequency HV Tester

Power supply requirement: AC50Hz, 220V, stability of frequency: fluctuation less than 0.5%. When using it, the capacitance of the sample should not exceed the rated capacity of the instrument. The overlow capacitance of the sample will affect the output wave form. If the capacitance is less than 0.05µF, the instrument cannot output normally. When using it, it is prohibited to boost voltage without load, or to connect with resistive load.

Product brief

The product combines modern advanced digital variable frequency technology and micro computer control together, therefore, it can realize the full automatic voltage boost, stepdown, measurement and protection as well as the manual intervention in the process of automatic voltage boost. The full electronic design ensures the small size and light weight. The big LCD screen ensures the clear and visual display, and can display the output wave form. The printer outputs test reports. In addition, the product has features as follows:

• Data of current, voltage, wave form can be directly sampled at high voltage side, so the data is real and accurate.
• Overvoltage protection: If the output exceeds the set limit of voltage, the instrument will shut-down to protect itself, the actuation time is less than 20ms.
• Overcurrent protection: it is high-low voltage dual protection in the design, the accurate shut-down protection can be made according to the set value at high voltage side; If the current on low voltage side exceeds the rated current, the instrument will take shut-down protection, the actuation time are both less than 20ms.
• A high voltage output protective resistor is provided in the voltage boost body in the design and this eliminates the need of additional protective resistor connected outside.

Technical parameters

1. Output voltage ratings: See Details of Table 1
2. Output frequency: 0.1Hz, 0.05Hz, 0.02Hz
3. Measurement accuracy: 3%
4. Positive and negative voltage peak errors: = 3%
5. Voltage wave form distortion: = 5%
6. Use condition: indoor and outdoor; temperature: -10??+40? Humidity: = 85%RH
7. Power: AC50Hz, 220V ±5%
8. Power supply fuse tube: See Details of Table 1

HIOKI 3238 Digital HiTester Benchtop 5-1/2 digits DMM with high-speed comparator and high-accuracy Multi functional and high precision model, with AC/DC current and Frequency measureme...
HIOKI 3805-50 Digital HiTester Demonstrate the Power of your DMM during Facilities Maintenance For Instrumentation (4 - 20mA% display). For Power line distortion check (Harmonic distor...
HIOKI 3245-60 Solar HiTester Environmentally-friendly DMM Hybrid power system incorporates both a solar-charged main battery and a backup battery. Pocket-sized CATIII (600V) and CATIV ...
HIOKI 3239-01 Digital HiTester Benchtop 5-1/2 digits DMM with 4-terminal resistance measurement and high-accuracy Multi functional and high precision model, with 4-terminal resistance ...
FLUKE 233/A Remote Display Automotive Digital Multimeter Kit By simply sliding the wireless display out of the Fluke 233/A’s meter body, the technician can place the display where it is m...